COVID-19: Brief Report
Particle Filtration Efficiency Testing of Sterilization Wrap Masks
Destiny F. Chau, Patrick O'Shaughnessy, Michael L. Schmitz
J Prev Med Public Health. 2021;54(1):31-36.   Published online December 22, 2020
DOI: https://doi.org/10.3961/jpmph.20.394
  • 4,546 View
  • 125 Download
  • 1 Crossref
AbstractAbstract PDFSupplementary Material
Objectives
Non-traditional materials are used for mask construction to address personal protective equipment shortages during the coronavirus disease 2019 (COVID-19) pandemic. Reusable masks made from surgical sterilization wrap represent such an innovative approach with social media frequently referring to them as “N95 alternatives.” This material was tested for particle filtration efficiency and breathability to clarify what role they might have in infection prevention and control.
Methods
A heavyweight, double layer sterilization wrap was tested when new and after 2, 4, 6, and 10 autoclave sterilizing cycles and compared with an approved N95 respirator and a surgical mask via testing procedures using a sodium chloride aerosol for N95 efficiency testing similar to 42 CFR 84.181. Pressure testing to indicate breathability was also conducted.
Results
The particle filtration efficiency for the sterilization wrap ranged between 58% to 66%, with similar performance when new and after sterilizing cycles. The N95 respirator and surgical mask performed at 95% and 68% respectively. Pressure drops for the sterilization wrap, N95 and surgical mask were 10.4 mmH2O, 5.9 mmH2O, and 5.1 mmH2O, respectively, well below the National Institute for Occupational Safety and Health limits of 35 mmH2O during initial inhalation and 25 mmH2O during initial exhalation.
Conclusions
The sterilization wrap’s particle filtration efficiency is much lower than a N95 respirator, but falls within the range of a surgical mask, with acceptable breathability. Performance testing of non-traditional mask materials is crucial to determine potential protection efficacy and for correcting misinterpretation propagated through popular media.
Summary

Citations

Citations to this article as recorded by  
  • Spunbond-Meltblown-Spunbond ou Tecido-Não-Tecido para proteção respiratória de trabalhadores da saúde
    Francieli Faustino, Helenize Ferreira Lima Leachi, Aline Franco Da Rocha, Renata Perfeito Ribeiro
    Revista SOBECC.2024;[Epub]     CrossRef

JPMPH : Journal of Preventive Medicine and Public Health
TOP