- Performance Evaluation of Emergency Medical Center.
-
Chul Hwan Kang, Yoon Kim, Pyung Soo Lee, Young Dae Kwon, Chang Yup Kim, Young Soo Shin
-
Korean J Prev Med. 1997;30(4):884-892.
-
-
-
Abstract
PDF
- Currently, there are 100 community emergency centers which expect to provide professional emergency care like Level 1 trauma centers in U.S.A. To evaluate Performance of emergency center, most studies have been widely adopted death rate based methods such as Trauma and Injury Severity Score(TRISS) and A Severity Characterization of Trauma(ASCOT). However, these methods are only applicable in situation where registration process of trauma patients is well established. Therefore, an alternative method should be applied to evaluate performance of emergency centers in Korea which does not have well-developed registration scheme. This study aims to develop new performance measures which are applicable to Korea and evaluate performance of 35 community emergency centers through new measures. The new measures are included that 'W-statistic' ; death rate calculated on the basis of International Classification based Injury Severity Score(ICISS), and 'the degree of severity' ; rate of severe trauma patients of each emergency medical centers. The study results can be summarized as follows. First, about 34% of sample emergency centers show they provide proper care in terms of their function. Second, tertiary hospitals, university hospitals, and hospitals located in Seoul show higher severity degree of patients and lower severity-adjusted death rate.
-
Summary
- Adoption and Its Determining Factors of Computerized Tomography in Korea.
-
Seok Jun Yoon, Sun Mean Kim, Chul Hwan Kang, Chang Yup Kim, Young Soo Shin
-
Korean J Prev Med. 1997;30(1):195-207.
-
-
-
Abstract
PDF
- High price equipment is one of the major factors that increases national health expenditure in developed countries. Computerized Tomography(CT), one of the important high price equipment, has been concerns of health service researchers and policy makers in many countries. In Korea, CT, first introduced in 1984, have spreaded nationwide with rapid speed. Though the Committee for Approving Import of High Price Medical Equipment, founded in 1981, tried to regulate the introduction of high price medical equipment including CT, the effort resulted in failure. The exact situation of diffusion of the high price equipment, however, was not yet investigated. We aimed at the description of the diffusion of CT in Korea and analysis of influencing factors in hospitals for the adoption of CT. We mainly used the database of CT, made in 1996 by the National Federation of Medical Insurance for the purpose of insurance payment for CT. Also characteristics of hospitals were gathered from yearbooks published by the central and local governments and by the Korean Hospital Association. We calculated the cumulative number of the CT per one million population year by year. In turn, multiple linear logistic regression was done to fine out the contributing factors for the adoption of CT by each hospital. In the logistic regression model, it is regarded as dependent factor whether a hospital retained CT or not in 1988 and 1993. The major categories of the independent factors were hospital characteristics, environmental factors and competitive conditions of hospitals at the period of the adoption. The results are as follows : Numberof CT scanners per one million persons in Korea marked more higher level compared with those of most OECD countries. Major influencing factors on the adoption of CT scanners were hospital characteristics, such as hospital referral level, and competitive condition of hospitals, such as number of CT scanners per 10,000 persons in each district where the hospital was located. In Korea, CT diffused with rather rapid speed, comparable with those of the United States and Japan. The major factors contributing on the adoption of CT for hospitals were competitive condition and hospital characteristics rather than regional health care need for Ct. In conclusion, a kind of regulating mechanism would be necessary for the prevention of the indiscreet adoption and inefficient use of high price equipment including CT.
-
Summary
|